Cordio HearO Voice Monitoring System Highly Sensitive, Predicts HF Events Days Early
William Abraham, MD, discusses the DETECT-HF trial and HearO’s sensitivity in discerning future HF events from fluid retention in voice recordings.
The Cordio HearO system, a new remote voice analysis system, has demonstrated its high sensitivity and low unexplained priority notification rate (UPNR) when detecting
These data were presented at the
“The great news is that this system can detect these worsening HF events well in advance, as demonstrated by the data,” Abraham told HCPLive in an exclusive interview. “That is huge because changes in patient symptoms and daily weights – our current standard-of-care way of doing this - only become apparent about 2 or 3 days before the hospitalization. Now, with this technology, we’ve got a very broad window of opportunity to intervene.”
The Cordio HearO system was developed to remotely monitor fluid status in HF patients by measuring changes in voice recordings over time. The system includes a mobile application, cloud-based analytics, and a web-based portal. The trial investigating its efficacy, DETECT-HF, was in turn designed to validate system performance to predict HF events with a predefined vocal biomarker algorithm, which had been developed in prior studies.1
Patients were eligible to enroll in DETECT-HF if they were ≥22 years old, had been diagnosed with symptomatic chronic HF with New York Heart Association (NYHA) class II-Iva, and had ≥1 from among the following criteria:
- 1 HF hospitalization within the last year
- 1 unplanned intravenous or subcutaneous diuretic administration in the last 6 months
- 2 unplanned intravenous or subcutaneous diuretic administrations in the last 12 months
- NT-proBNP>500 pg/mL
Patients with a major cardiovascular event within 3 months before enrollment, a Cardiac Resynchronization Therapy Device (CRT) implanted or upgraded ≤1 month prior to screening, or prior treatment for a significant COPD, among other criteria, were excluded.2
DETECT-HF was a prospective, international, multicenter, single-arm, blinded, non-interventional study. Abraham and colleagues collected daily voice recordings to establish a baseline and identify changes predictive of HF events. True positives were defined as adjudicated HF events occurring within 31 days of the voice change and alert generation.1
Patients were followed until 76 adjudicated first HF events occurred or ≤2 years. Co-primary endpoints were the system’s sensitivity in detecting adjudicated first HF events, particularly HF hospitalizations or outpatient events requiring intravenous treatment, compared to a predefined performance criterion (sensitivity lower confidence bound of 60%), as well as UPNR rates compared to a predefined performance criterion (UPNR <3 per person/year).1
A total of 563 patients were enrolled in the study across 46 sites in the US, Israel, and Spain. The mean age among these patients was 67.6 (11.53) years, and 59.1% spoke English, 20.8% spoke Hebrew, 15.5% spoke Spanish, 3.2% spoke Russian, and 1.4% spoke Arabic. By the end of the study, Abraham and colleagues had found that the system demonstrated 68.4% sensitivity in predicting first HF events (52 of 76 events; 95% CI, 58 to 78.9%; P = .0573). In the analysis including all HF events, the system demonstrated 70.5% sensitivity (80 of 112 events; 95% CI, 60.8 to 78.7%).1
HF events were predicted, on average, 24.6 days prior to the event, and UPNR values were well below the predefined performance goal (2.65; 95% CI, 2.53 to 2.76; P = .001). Average compliance with daily voice recordings was 85%, and the usability questionnaire distributed to patients revealed that the system was considered highly usable – mean scores ranged from 4.7 to 4.9 on a 5-point scale.1
Ultimately, Abraham and colleagues concluded that this device is capable of detecting HF events early and reliably, allowing for earlier intervention and a potentially decreased risk of hospitalization. However, the team also acknowledges the need for further research, particularly into discerning between fluid retention due to HF and retention due to other conditions.1
“We know that, with this type of technology, there are other things that can affect speech. These may be picked up as well,” Abraham said. “Respiratory infections, worsening HF events that didn’t meet the threshold, and renal events might result in fluid retention that’s independent of, or not related to, heart failure per se. But I think the bottom line is that these notifications are, by and large, valuable in any event, since they tell us that there’s likely to be something going wrong with the patient.”
Editors’ Note: Abraham reports disclosures with CVRx, J&J V-Wave, Sensible Medical, scPharmaceuticals, WhiteSwell, Bioventrix, and others.
References
Abraham W, Amir O, Bayes-Genis A, et al. Results of a Prospective, International, Multicenter, Pivotal Validation Study of Remote Voice Analysis for Monitoring Ambulatory Heart Failure Patients. Presented at the American Heart Association (AHA) Scientific Sessions 2026, Chicago, IL. November 6-9, 2026.
Cordio Medical. An International, Observational, Blinded Study to Assess the Performance of the Cordio HearO System (DETECT-HF). ClinicalTrials.gov Identifier: NCT06378632. Updated November 6, 2026. Accessed November 23, 2026.
https://clinicaltrials.gov/study/NCT06378632?term=NCT06378632&rank=1
Related to this article